Алфавитный указатель терминов на английском языке
Absorbability ....................................................................................................................... | A.6 |
Absorber plate ...................................................................................................................... | 7.7 |
Active heating system .......................................................................................................... | 6.2 |
Air mass .............................................................................................................................. | A.13 |
Air-type solar collector ......................................................................................................... | 7.3 |
Aperture angle ..................................................................................................................... | 4.25 |
Area of absorber plate .......................................................................................................... | 7.9 |
Auxiliary heater of solar heating system................................................................................ | 6.10 |
Bifacial solar cell ................................................................................................................. | 3.10 |
Black absorptive coating ...................................................................................................... | 7.20 |
Cavity receiver of solar insulation......................................................................................... | 4.17 |
Central receiver ................................................................................................................... | 4.16 |
Collector efficiency............................................................................................................... | 7.11 |
Collector efficiency factor..................................................................................................... | 7.16 |
Collector instantaneous efficiency......................................................................................... | 7.12 |
Collector overal heat-loss coefficient .................................................................................... | 7.14 |
Collector-storage water heater .............................................................................................. | 7.5 |
Combined photovoltaic (PV) module for production of heat and electricity ........................... | 5.3 |
Cooling system of solar cells ................................................................................................ | 5.8 |
Diffuse radiation................................................................................................................... | A.4 |
Direct-heating solar system .................................................................................................. | 6.7 |
Direct radiation .................................................................................................................... | A.3 |
Double-loop heating system.................................................................................................. | 6.8 |
Double-loop solar power plant............................................................................................... | 4.4 |
Efficiency of solar cell, module, array................................................................................... | 5.9 |
Efficiency of solar power plant.............................................................................................. | 4.23 |
Emittance of surface............................................................................................................. | A.9 |
Energy storage system........................................................................................................... | 4.20 |
Equilibrium temperature ...................................................................................................... | 7.19 |
Evacuated receiver ............................................................................................................... | 4.15 |
Evacuated tube solar collector .............................................................................................. | 7.6 |
Flat-plate solar collector........................................................................................................ | 7.1 |
Flowing-type solar collector.................................................................................................. | 7.4 |
Fluid-type solar collector....................................................................................................... | 7.2 |
Function of heat load supplied by solar heating system.......................................................... | 6.13 |
Heating................................................................................................................................. | A.2 |
Heat-loss coefficient through transparent cover .................................................................... | 7.15 |
Heat reflected coating............................................................................................................ | 7.22 |
Heliostat .............................................................................................................................. | 4.13 |
Heliostat field....................................................................................................................... | 4.14 |
Maximum power of photovoltaic solar cell, module, array, power plant................................ | 5.14 |
Mirror booster ..................................................................................................................... | 4.9 |
Mirror coating ..................................................................................................................... | A.12 |
Mirror faceted concentrator................................................................................................... | 4.12 |
Modular solar power plant.................................................................................................... | 4.5 |
Optical concentrating system ............................................................................................... | 4.8 |
Optical efficiency ................................................................................................................. | 4.24 |
Optical efficiency of solar collector....................................................................................... | 7.13 |
Optical sensor ...................................................................................................................... | 4.22 |
Paraboloic trough concentrator ............................................................................................. | 4.10 |
Paraboloid concentrator ....................................................................................................... | 4.11 |
Passive heating system.......................................................................................................... | 6.3 |
Peak power of solar, cell, module, array, power plant............................................................ | 5.13 |
Power engineering ............................................................................................................... | A.1 |
Solar collector heating capacity ........................................................................................... | 7.10 |
Capacity of solar heating system........................................................................................... | 6.11 |
Photovoltaic (PV) module..................................................................................................... | 5.1 |
Concentrating photovoltaic (PV) module ............................................................................. | 5.2 |
Photovoltaic solar power plant.............................................................................................. | 4.2 |
Receiver of solar energy ....................................................................................................... | 4.7 |
Reflectance .......................................................................................................................... | A.8 |
Selective absorptive coating.................................................................................................. | 7.21 |
Selective coating.................................................................................................................. | A.10 |
Selective coefficient ............................................................................................................. | A.11 |
Solar cell............................................................................................................................... | 3.8 |
Solar collector ...................................................................................................................... | 3.13 |
Solar collector heat removal factor........................................................................................ | 7.17 |
Solar cooling ........................................................................................................................ | 3.6 |
Solar cooling system............................................................................................................. | 6.5 |
Solar economizer ................................................................................................................. | 4.19 |
Solar energy concentrator .................................................................................................... | 3.14 |
Solar-fuel power plant. ......................................................................................................... | 3.3 |
Solar heating ........................................................................................................................ | 3.4 |
Solar heating system............................................................................................................. | 6.4 |
Solar heating and cooling ..................................................................................................... | 3.7 |
Solar heating and cooling system ......................................................................................... | 6.6 |
Solar photovoltaic (PV) array................................................................................................ | 5.4 |
Solar power engineering ...................................................................................................... | 3.1 |
Photovoltaic solar power plant.............................................................................................. | 4.2 |
Solar photovoltaic cell........................................................................................................... | 3.9 |
Solar steam generator ........................................................................................................... | 4.18 |
Solar thermoelectric element................................................................................................. | 3.11 |
Solar thermoionic converter ................................................................................................. | 3.12 |
Solar tower plant .................................................................................................................. | 4.3 |
Solar tracker......................................................................................................................... | 5.6 |
Solar tracking system ........................................................................................................... | 4.21 |
Solar water heating............................................................................................................... | 3.5 |
Solar hot-water system ......................................................................................................... | 6.1 |
Specific flowrate of heat transfer fluid................................................................................... | 7.18 |
Specific capacity of solar heating system .............................................................................. | 6.12 |
Standard test conditions for solar cell, module, array ............................................................ | 5.12 |
Support................................................................................................................................. | 5.5 |
Temperature coefficients of current, voltage ......................................................................... | 5.11 |
Thermochemical cycle of solar energy conversion ................................................................ | 4.6 |
Thermodynamic solar power plant ....................................................................................... | 4.1 |
Thermosyphon solar heating system ..................................................................................... | 6.9 |
Total radiation...................................................................................................................... | A.5 |
Tracking system of photovoltaic plant................................................................................... | 5.7 |
Voltage-current characteristics of solar cell, photovoltaic module, array................................ | 5.10 |
Transparent cover insulation of solar collector...................................................................... | 7.8 |
Transmittance ...................................................................................................................... | A.7 |
|
|
|
|
|
|
|
|
ГОСТ Р 51677-2000
УДК 621.313.281:006.354 Е61
ГОСУДАРСТВЕННЫЙ СТАНДАРТ РОССИЙСКОЙ ФЕДЕРАЦИИ
Машины электрические асинхронные мощностью от 1 до 400 кВт включительно
ДВИГАТЕЛИ
Показатели энергоэффективности
Asynchronous electrical machines of power from 1 to 400 kW inclusive.
Motors. Efficiency and power factors
ОКС 29.160.30
ОКСТУ 3320
3330
Дата введения 2001—07—01
Предисловие
1 РАЗРАБОТАН Научно-исследовательским проектно-конструкторским и технологическим институтом электромашиностроения (НИПТИЭМ)
ВНЕСЕН Техническим комитетом по стандартизации ТК 333 «Машины электрические вращающиеся»
2 ПРИНЯТ И ВВЕДЕН В ДЕЙСТВИЕ Постановлением Госстандарта России от 7 декабря 2000 г. № 333-ст
3 ВВЕДЕН ВПЕРВЫЕ
ОБЛАСТЬ ПРИМЕНЕНИЯ
Настоящий стандарт распространяется на трехфазные асинхронные двигатели с короткозамкнутым ротором общего назначения мощностью от 1 до 400 кВт включительно (далее — двигатели) для работы от сети переменного тока напряжением до 690 В, изготовляемые для нужд народного хозяйства и экспорта.
Стандарт не распространяется на специальные двигатели, устанавливаемые на средствах наземного, морского и воздушного транспорта, взрывозащищенные двигатели, а также на двигатели, работающие в нестационарных режимах, многоскоростные двигатели и двигатели с повышенным скольжением.
Стандарт устанавливает уровни показателей энергоэффективности (энергетических показателей): коэффициента полезного действия (КПД) и коэффициента мощности, а также методы их определения.
Требования настоящего стандарта являются обязательными.
НОРМАТИВНЫЕ ССЫЛКИ
В настоящем стандарте использованы ссылки на следующие стандарты:
ГОСТ 183—74 Машины электрические вращающиеся. Общие технические условия
ГОСТ 7217—87 Машины электрические вращающиеся. Двигатели асинхронные. Методы испытаний
ГОСТ 28330—89 Машины электрические асинхронные мощностью от 1 до 400 кВт включительно. Двигатели. Общие технические требования
ОПРЕДЕЛЕНИЯ
В настоящем стандарте применяют следующие термины с соответствующими определениями.
3.1 двигатели с нормальным КПД: Двигатели общепромышленного назначения, КПД которых соответствует уровню, достигнутому в производстве двигателей серии АИ.
3.2 двигатели с повышенным КПД (энергосберегающие двигатели): Двигатели общепромышленного назначения, у которых суммарные потери мощности не менее чем на 20 % меньше суммарных потерь мощности двигателей с нормальным КПД той же мощности и частоты вращения.
КПД энергосберегающего двигателя hэ, %, при различных уровнях снижения суммарных потерь определяют по формуле
, (1)
где h — коэффициент полезного действия двигателя с нормальным КПД, %;
е ³ 0,2 — относительное снижение суммарных потерь мощности в двигателе, о.е.
Минимальные значения КПД энергосберегающего двигателя (для случая снижения суммарных потерь мощности в двигателе на 20 %, т.е. при е = 0,2), hэм, %, определяют по формуле
, (2)
ОСНОВНЫЕ ПАРАМЕТРЫ И РАЗМЕРЫ
Основные параметры и размеры двигателей — по ГОСТ 28330.
ТЕХНИЧЕСКИЕ ТРЕБОВАНИЯ
5.1 Показателями энергоэффективности являются:
- коэффициент полезного действия, представляющий отношение полезной мощности на валу двигателя, выраженной в киловаттах, к активной мощности, потребляемой двигателем из сети, выраженной в киловаттах;
- коэффициент мощности, представляющий отношение потребляемой активной мощности, выраженной в киловаттах, к полной мощности, потребляемой из сети, выраженной в киловольтамперах.
5.2 В зависимости от требований к уровню энергоэффективности двигатели подразделяют на:
- двигатели с нормальным КПД;
- двигатели с повышенным КПД (энергосберегающие двигатели).
5.3 Двигатели с нормальным КПД мощностью от 1 до 400 кВт включительно должны иметь номинальные значения КПД и коэффициента мощности не ниже указанных в таблицах 1 и 2.
Таблица 1 — Значения КПД двигателей с нормальным КПД
Номинальная мощность, кВт | КПД двигателей, %, при числе полюсов | |||||
2р = 2 | 2р = 4 | 2р = 6 | 2р = 8 | 2р = 10 | 2р = 12 | |
1,10 | 77,0 | 75,0 | 72,0 | 72,0 | — | — |
1,50 | 79,0 | 77,0 | 77,0 | 73,0 | — | — |
2,20 | 82,0 | 78,0 | 80,0 | 75,0 | — | — |
3,00 | 82,0 | 79,0 | 81,0 | 78,0 | — | — |
4,00 | 83,0 | 83,0 | 82,0 | 82,0 | — | — |
5,50 | 86,0 | 84,0 | 84,0 | 83,0 | — | — |
7,50 | 87,0 | 87,0 | 84,5 | 85,0 | — | — |
11,0 | 88,0 | 88,0 | 87,0 | 87,0 | — | — |
15,0 | 89,0 | 89,0 | 88,5 | 88,0 | — | — |
18,5 | 90,0 | 90,0 | 89,0 | 88,5 | — | — |
22,0 | 90,5 | 90,5 | 90,0 | 89,5 | — | — |
30,0 | 91,0 | 91,5 | 90,0 | 90,0 | 88,5 | — |
37,0 | 92,0 | 92,0 | 91,0 | 91,0 | 89,0 | — |
45,0 | 92,5 | 92,5 | 92,0 | 92,0 | 91,0 | 90,5 |
55,0 | 93,0 | 93,0 | 92,5 | 92,0 | 92,0 | 91,0 |
75,0 | 93,0 | 93,5 | 92,5 | 92,5 | 92,0 | 91,5 |
90,0 | 93,0 | 94,0 | 93,0 | 93,0 | 92,5 | 92,0 |
110,0 | 93,5 | 94,0 | 93,0 | 93,0 | 93,0 | 92,0 |
132,0 | 94,0 | 94,0 | 93,5 | 93,5 | 93,0 | — |
160,0 | 94,0 | 94,0 | 94,0 | 93,5 | — | — |
200,0 | 94,5 | 94,5 | 94,5 | 94,0 | — | — |
250,0 | 94,5 | 94,5 | 94,5 | — | — | — |
315,0 | 95,0 | 95,0 | — | — | — | — |
400,0 | 95,5 | 95,5 | — | — | — | — |
Таблица 2 — Значения коэффициента мощности двигателей с нормальным и повышенным КПД
Номинальная мощность, кВт | Коэффициент мощности двигателей о е , при числе полюсов | |||||
2р = 2 | 2р = 4 | 2р = 6 | 2р = 8 | 2р = 10 | 2р = 12 | |
1,10 | 0,80 | 0,76 | 0,70 | 0,68 | — | — |
1,50 | 0,82 | 0,78 | 0,70 | 0,70 | — | — |
2,20 | 0,84 | 0,80 | 0,72 | 0,70 | — | — |
3,00 | 0,85 | 0,80 | 0,72 | 0,70 | — | — |
4,00 | 0,84 | 0,81 | 0,75 | 0,70 | — | — |
5,50 | 0,85 | 0,82 | 0,76 | 0,72 | — | — |
7,50 | 0,85 | 0,83 | 0,77 | 0,72 | — | — |
11,0 | 0,86 | 0,83 | 0,80 | 0,73 | — | — |
15,0 | 0,86 | 0,84 | 0.82 | 0,75 | — | — |
18,5 | 0,87 | 0,84 | 0,82 | 0,75 | — | — |
22,0 | 0,87 | 0,84 | 0,82 | 0,75 | — | — |
30,0 | 0,88 | 0,85 | 0,82 | 0,75 | 0,70 | — |
37,0 | 0,88 | 0,85 | 0,82 | 0,75 | 0,70 | — |
45,0 | 0,88 | 0,85 | 0,82 | 0,75 | 0,72 | 0,70 |
55,0 | 0,88 | 0,85 | 0,82 | 0,75 | 0,72 | 0,70 |
75,0 | 0,89 | 0,85 | 0,82 | 0,80 | 0,75 | 0,70 |
90,0 | 0,89 | 0,86 | 0,83 | 0,80 | 0,75 | 0,70 |
110,0 | 0,89 | 0,86 | 0,83 | 0,82 | 0,75 | 0,70 |
132,0 | 0,89 | 0,87 | 0,85 | 0,82 | 0,78 | — |
160,0 | 0,89 | 0,87 | 0,85 | 0,82 | — | — |
200,0 | 0,90 | 0,87 | 0,85 | 0,82 | — | — |
250,0 | 0,90 | 0,88 | 0,86 | — | — | — |
315,0 | 0,90 | 0,88 | — | — | — | — |
355,0 | 0,90 | 0,89 | — | — | — | — |
400,0 | 0,90 | 0,89 | — | — | — | — |
5.4 Двигатели с повышенным КПД (энергосберегающие двигатели) мощностью от 15 до 400 кВт включительно должны иметь номинальные значения КПД и коэффициента мощности не ниже указанных в таблицах 3 и 2.
Значения КПД, указанные в таблице 3, определены по формуле (2).
Таблица 3 — Значения КПД двигателей с повышенным КПД
Номинальная мощность, кВт | КПД двигателей, %, при числе полюсов | |||||
2р = 2 | 2р = 4 | 2р = 6 | 2р = 8 | 2р = 10 | 2р = 12 | |
15,0 | 91,3 | 91,8 | 90,6 | 90,0 | — | — |
18,5 | 91,8 | 92,2 | 91,0 | 90,6 | — | — |
22,0 | 92,3 | 92,6 | 91,8 | 91,4 | — | — |
30,0 | 92,9 | 93,7 | 91,8 | 91,8 | 90,6 | — |
37,0 | 93,5 | 93,7 | 92,7 | 92,7 | 91,0 | — |
45,0 | 93,9 | 93,9 | 93,5 | 93,5 | 92,7 | 92,3 |
55,0 | 94,3 | 94,3 | 93,9 | 93,5 | 93,5 | 92,7 |
75,0 | 94,6 | 94,7 | 93,9 | 93,9 | 93,5 | 93,1 |
90,0 | 95,0 | 95,1 | 94,3 | 94,3 | 93,9 | 93,5 |
110,0 | 94,7 | 95,1 | 94,3 | 94,3 | 94,3 | 93,5 |
132,0 | 95,1 | 95,1 | 94,7 | 94,7 | 94,3 | — |
160,0 | 95,1 | 95,1 | 95,1 | 94,7 | — | — |
200,0 | 95,5 | 95,5 | 95,5 | 95,1 | — | — |
250,0 | 95,5 | 95,5 | 95,5 | — | — | — |
315,0 | 96,0 | 96,0 | — | — | — | — |
400,0 | 96,4 | 96,4 | — | — | — | — |
5.5 Номинальные значения показателей энергоэффективности (КПД и коэффициента мощности) указывают в технических условиях на двигатели конкретных типов.
5.6 Допускаемые отклонения от номинальных значений показателей энергоэффективности — в соответствии с требованиями ГОСТ 183.
МАРКИРОВКА
Маркировка двигателей с повышенным КПД — по ГОСТ 28330.
При маркировании в условном обозначении двигателей с повышенным КПД применяют строчную букву е, которую располагают после цифры, обозначающей число полюсов двигателя.
Пример условного обозначения асинхронного двигателя серии 5А высотой оси вращения 180 мм, длиной S, двухполюсного, с повышенным КПД, климатического исполнения Т2:
5 A 180 S 2 eT 2
МЕТОДЫ КОНТРОЛЯ
Методы испытаний двигателей — по ГОСТ 7217.
ГОСТ Р 51689-2000
УДК 621.313.33:006.354 Группа Е60
ГОСУДАРСТВЕННЫЙ СТАНДАРТ РОССИЙСКОЙ ФЕДЕРАЦИИ
Дата добавления: 2019-07-15; просмотров: 202; Мы поможем в написании вашей работы! |
Мы поможем в написании ваших работ!